TJERNLUND SIDESHOT SS2 OIL & GAS SIDE WALL VENTING SYSTEM

TJERNLUND SIDESHOT SS2 OIL & GAS SIDE WALL VENTING SYSTEM
Normal Price: $0.00
Our Price: $611.88

Weight: 0.00 lbs.

Select Model / Parts: 
Quantity: 
Tjernlund SS2 OIL & GAS SIDE WALL VENTING SYSTEM. Enhanced 2nd Generation product design. Eliminates need for chimney venting. Saves on installation and repair of chase and chimney while increasing living space. No pre-installation assembly required. Includes UC1 Burner Interlock Control.

 

THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED HVAC CONTRACTOR.

TJERNLUND SIDESHOT SS2 PRODUCT FEATURES

Self-cleaning stainless steel impellar and sealed ball bearing motor makes the SS2 virtually maintenace free. Backward inclined impellar blades resist soot build-up, reducing vibration and noise problems. Cooling fan forces room air directly over motor, extending its life.
 
Pre-wired operation and safety controls.
Stainless steel construction.
Self-cleaning Blower Wheel.
Ultra-fine Draft Adjustment.
Slide-out Venter assembly.
Zero Clearance installation to combustibles.
Patented High-Velocity Exhaust prevents building exterior staining.
Quiet Operation with vibration absorbing mounting brackets.
Energy efficient.
Weather protected operating components.
 
TJERNLUND SIDESHOT SS2 (Oil & Gas) APPLICATION GUIDE

NOTE: Verify that the total BTU/hr. input of the heating appliance(s) fall within the proper catagory listed. The maximum equivalent feet and capacity differs between the SS1 and SS1C. To determine equivalent feet - add the total length of straight pipe plus 10 feet for each 90 degree elbow and 5 feet for each 45 degree elbow. Vent runs over 15 linear feet should use an approved, insulated vent connector to prevent sulfur condensation problems.
 
MODEL SS2 -  For capacities up to 168,000 BTU/hr. Flame Retention Oil Burner - 70,000 to 168,000 BTU/hr. Fan Assisted Natural & LP Gas - 40,000 to 150,000 BTU/hr. Atmospheric Natural & LP Gas - 40,000 to 125,000 BTU/hr. Max. Equivalent Feet - 50
 
CALCULATE OIL BTU/hr. INPUT ON NOZZLE SIZE AND ACTUAL PUMP PRESSURE. MAXIMUM CAPACITY BASED ON 13% CO2 / MAX 500F INLET TEMPERATURE.
 
MODELS SS2 INCLUDES UC1 BURNER INTERLOCK CONTROL.

Simplifies new installations and service calls.
Operation and wiring interlock problems are diagnosed and displayed with LED indicators.
Adjustable Pre / Post purge.
Prover switch delay eliminates burner start up or wind induced prover switch short cycling.
Interlock voltage can be selected (24 or 115VAC). Eliminates false triggering by burner monitoring circuits.
 
 
 
FOR ADDITIONAL TECHNICAL & INSTALLATION INFORMATION VISIT TJERNLUND WEBSITE AT WWW.TJERNLUND.COM. CLICK ON DOCUMENT LIBRARY.